C2.2 | D30

C2.2 | D30 Generator Set

THE RUNDOWN

Cat® C2.2 Engine
  • Reliable, rugged, durable design
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
Alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Industry leading mechanical and electrical design
    • High efficiency
    GCCP 1.2 Control Panel
    • User-friendly interface and navigation
    • Scalable system to meet a wide range of installation requirement
    • Expansion modules and site-specific programming for specific customer requirements
    • Image may not be a representative of actual product
    Cooling System
    • Designed to operate in standard ambient temperatures up to 40°C (104°F)
    • Contact your Cat Dealer for specific ambient and altitude capabilities
    Full range of attachments
    • IP23 Alternators
    • Anti-vibration mounts
    • UL142 compliant
    • 24, 48 and 72 hour fuel tanks with option of skid base
    • Factory fitted telematics
    Footprint
    • Compact design allows for improved packaging, resulting in the smallest genset footprint
    Generator Set Specifications
    Standby Rating29.6 ekW
    Frequency60 Hz
    Emissions/Fuel StrategyU.S. EPA Tier 4i Certified
    Voltage480/277, 240/120, 208/120, 600/346, 240/120 VAC
    Speed1800 rpm
    Duty CycleStandby
    Engine Specifications
    Engine ModelCat® C2.2, In-line 4, 4-cycle diesel
    Bore3.3in
    Stroke3.9in
    Compression Ratio23.3:1
    AspirationTurbocharged air to air charge cooling
    Fuel SystemElectronically actuated Mechanical Cassette type
    Governor TypeMechanical
    Generator Set Dimensions
    Length - Maximum88.6in
    Width - Maximum41.3in
    Height - Maximum57.9in
    Dry Weight - Genset (maximum)2052lb
    Standard Equipment

    Engine

    • Diesel Engine 2.2L, U.S EPA TIER IV Interim

    Air Inlet

    • Standard air cleaner

    Exhaust System

    • Dry exhaust manifold

    Fuel System

    Base Type

    • Standard wide skid base

    Control Panel

    Control Panel and Governing

    • GCCP 1.2, Mechanical Governor

    Telematics

    • Cat® Product Link™ PL444 cellular

    Generators and Generator Attachments

    • 1-Phase and 3-Phase
    • M-Frame

    Starting / Charging System

    • Starter Motor / Standard Battery

    Circuit Breakers

    • Single / Multi LSI

    General

    • Standard Radiator, Turbo and Manifold guards
    • Paint - Caterpillar yellow except rails are gloss black

    Controls

    • AVR, Current Transformer
    Optional Equipment

    Certifications

    • IBC, UL2200

    Air Inlet

    Alternator and Attachments

    • Space Heater
    • PM Excitation
    • Fault relay, Mounting/Duct plate

    Cooling System

    Exhaust

    • Level 2 / Enclosure silencer
    • Silencer install kit

    Power Connection

    • Shunt trip / Neutral bars

    Telematics

    Enclosures

    • Sound attenuated steel & aluminum

    Controls

    • Input expansion module / NFPA bundle
    • GFCI, Ground fault relay, E-Stop
    • Remote Annunciator, Panel audible alarm

    Mufflers

    Fuel Storage

    • Fuel level switch and alarm
    • Fill pipe, Spill containment, Overfill protection
    • Fuel tank riser / Vent pipe with extension
    • Integral tank- 24 / 48 / 72 Hrs

    Starting / Charging System

    Others

    • Jacket water heater, Battery charger