C2.2 | D25 Generator Set
THE RUNDOWN
Cat® C2.2 Engine
- Reliable, rugged, durable design
- Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
Alternator
- High efficiency
GCCP 1.2 Control Panel
- User-friendly interface and navigation
- Scalable system to meet a wide range of installation requirement
- Expansion modules and site-specific programming for specific customer requirements
- Image may not be a representative of actual product
Cooling System
- Designed to operate in standard ambient temperatures up to 40°C (104°F)
- Contact your Cat Dealer for specific ambient and altitude capabilities
Full range of attachments
- IP23 Alternators
- Anti-vibration mounts
- UL142 compliant
- 24, 48 and 72 hour fuel tanks with option of skid base
- Factory fitted telematics
Footprint
- Compact design allows for improved packaging, resulting in the smallest genset footprint
Generator Set Specifications
| Standby Rating | 25.0 ekW |
| Frequency | 60 Hz |
| Emissions/Fuel Strategy | U.S. EPA Tier 4i Certified |
| Voltage | 480/277, 240/120, 208/120, 600/346, 240/120 VAC |
| Speed | 1800 rpm |
| Duty Cycle | Standby |
Engine Specifications
| Engine Model | Cat® C2.2, In-line 4, 4-cycle diesel |
| Bore | 3.3in |
| Stroke | 3.9in |
| Displacement | 134in³ |
| Compression Ratio | 23.3:1 |
| Aspiration | Turbocharged |
| Fuel System | Mechanical Cassette Type |
| Governor Type | Mechanical |
Generator Set Dimensions
| Length - Maximum | 88.6in |
| Width - Maximum | 41.3in |
| Height - Maximum | 57.9in |
| Dry Weight - Genset (maximum) | 2052lb |
Standard Equipment
Engine
- Diesel Engine 2.2L, U.S EPA TIER IV Interim
Air Inlet
- Standard air cleaner
Exhaust System
- Dry exhaust manifold
Fuel System
Base Type
- Standard wide skid base
Control Panel
Control Panel and Governing
- GCCP 1.2, Mechanical Governor
Telematics
- Cat® Product Link™ PL444 cellular
Generators and Generator Attachments
- 1-Phase and 3-Phase
- M-Frame
Starting / Charging System
- Starter Motor / Standard Battery
General
- Standard Radiator, Turbo and Manifold guards
- Paint - Caterpillar yellow except rails are gloss black
Circuit Breakers
- Single / Multi LSI
Controls
- AVR, Current Transformer
Optional Equipment
Air Inlet
Certifications
- IBC, UL2200
Cooling System
Alternator and Attachments
- Space Heater
- PM Excitation
- Fault relay, Mounting/Duct plate
Exhaust
- Silencer install kit
- Level 2 / Enclosure silencer
Telematics
Power Connection
- Shunt trip / Neutral bars
Enclosures
- Sound attenuated steel & aluminum
Mufflers
Controls
- Remote Annunciator, Panel audible alarm
- Input expansion module / NFPA bundle
- GFCI, Ground fault relay, E-Stop
Starting / Charging System
Fuel Storage
- Fuel tank riser / Vent pipe with extension
- Integral tank- 24 / 48 / 72 Hrs
- Fuel level switch and alarm
- Fill pipe, Spill containment, Overfill protection
Others
- Jacket water heater, Battery charger