3516C (50 Hz) with Upgradeable Package
THE RUNDOWN
Cat® Diesel Engine
- Rugged, durable design with reliable performance proven in thousands of applications worldwide
- Certified alternative fuels including Hydrotreated Vegetable Oil (HVO), Renewable Diesel (RD) and Hydrotreated Renewable Diesel (HRD) which meet EN 15940 or ASTM D975 can be used or blended with EN 590 diesel
Cat Generator Set Package
- Accepts 100% block load in one step
- Meets NFPA 110 loading requirements
- Conforms to ISO 8528-5 G3 load acceptance requirements
- Reliability verified through torsional vibration, fuel consumption, oil consumption, transient performance, and endurance testing
Alternators
- Superior motor starting capability minimizes need for oversizing generator
- Designed to match performance and output characteristics of Cat diesel engines
EMCP 4 Control Panel
- User-friendly interface and navigation
- Scalable system to meet a wide range of installation requirement
- Expansion modules and site-specific programming for specific customer requirements
Cooling System
- Cooling systems are available to operate in ambient temperatures up to 50°C (122°F)
- Tested to ensure proper generator set cooling
Warranty
- 24 months/1000-hour warranty for Standby and Mission Critical ratings
- 12 months/unlimited hour warranty for Prime and Continuous ratings
- 12 months/unlimited hour warranty for Prime-DCP ratings
- Extended service protection is available to provide extended coverage options
Worldwide Product Support
- Cat dealers have over 1,800 dealer branch stores operating in 200 countries
- Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Financing
- Caterpillar offers an array of financial products to help you succeed through financial service excellence
- Options include loans, finance lease, operating lease, working capital, and revolving line of credit
- Contact your local Cat dealer for availability in your region
Generator Set Specifications
| Standby Rating | 2750 kVA |
| Prime Power Rating | 2500 kVA |
| Emissions/Fuel Strategy | Low Fuel Consumption |
| Voltage | 380 to 11000 volts |
| Frequency | 50 Hz |
| Speed | 1500 rpm |
| Duty Cycle | Standby, Mission Critical, Prime, Continuous |
| Maximum Rating | 2750 kVA |
| Minimum Rating | 2275 kVA |
Engine Specifications
| Engine Model | 3516C, ATAAC, V-16,4-Stroke Water-Cooled Diesel |
| Bore | 6.69in |
| Stroke | 8.46in |
| Displacement | 4765in |
| Compression Ratio | 14:01 |
| Aspiration | TA |
| Fuel System | Electronic unit injection |
| Governor Type | Adem™3 |
Generator Set Dimensions
| Length - Maximum | 228.3in |
| Width - Maximum | 75.9in |
| Height - Maximum | 80.7in |
| Dry Weight - Genset (maximum) | 32404lb |
Standard Equipment
Air Inlet System
- Air cleaner
- Single element canister type with service indicator
Control Panel
- RPM
- Engine cycle crank
- Failure to start (overcrank)
- Warning/shutdown with common LED indication of shutdowns for:
- Speed adjust
- True RMS AC metering, 3-phase, +/-2% accuracy
- Overcurrent (50/51)
- Controls:
- Generator phase sequence
- Low oil pressure
- 2 Programmable digital outputs
- Reverse power (kW) (32)
- Operating hours
- Frequency (Hz)
- kVAr-hr (total)
- kVA (per phase, average & percent)
- Lamp test
- Over/under frequency (81 o/u)
- 6 programmable digital inputs
- 2 Programmable relay outputs (Form C)
- 24 Volt DC operation
- Customer data link (Modbus RTU)
- EMCP 4 Genset controller
- Volts (L-L & L-N)
- High coolant temperature
- Alarm acknowledge
- Oil pressure (psi, kPa or bar)
- 4 Programmable relay outputs (Form A)
- Overspeed
- EMCP4.2B controller includes:
- Engine cool-down timer
- Panel lights
- kW (per phase, average & percent)
- Low coolant temperature
- Over/under voltage (27/59)
- Serial annunciator module data link
- Communications:
- Digital indication for:
- Text alarm/event descriptions
- EMCP 4.2B
- Coolant temperature
- Emergency stop pushbutton
- Programmable protective relaying functions:
- kW-hr (total)
- Reverse reactive power (kVAr) (32RV)
- Amps (per phase & average)
- Environmental sealed front face
- Power factor (per phase & average)
Exhaust
- Exhaust flange outlet
Fuel
- Primary fuel filter with integral water separator
Air Cleaner
- Single element with service indicator
Generator
- IP23 Protection
- Matched to the performance and output characteristics of Cat engines
Starting
- Heavy duty electric starter(s)
Starting/Charging
- Heavy duty starting system
- Charging alternator
Cooling
- ATAAC
- Standard Ambient Radiator
- Package mounted radiator
Crankcase Ventilation System
- Non filtered crankcase ventilation
Cooling System
- Fan and belt guards
- Coolant drain line with valve
- JWAC
- Caterpillar extended life coolant
- Radiator fan and fan drive
Exhaust System
- Flanged faced outlet(s)
- Dry exhaust manifold
Fuel System
- Flexible fuel lines - shipped loose
- Fuel priming pump
- Fuel cooler; not included with packages without radiator
- Secondary fuel filters
Generators and Attachments
- NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime / 150C standby).
- Busbar connections, top center mounted, top cable entry
- Random wound
- 6 Lead
- Winding temperature detectors
- IEC standard hole pattern
- Internal excitation (IE)
- 3 phase brushless, Salient pole
- Generator set packages include Caterpillar's digital voltage regulator (CDVR). CDVR includes reactive droop capability, 3-phase voltage sensing, KVAR/PF modes, RFI suppression, min/max exciter
Governing System
- ADEM III
Literature
- Parts book
- Operation & Maintenance Manual
Lube System
- Integral lube Oil cooler
- Fumes disposal
- Lubricating oil
- Oil filter, filler and dipstick
- Oil drain lines and valve
Mounting System
- Rails
- Rubber anti-vibration mounts - shipped loose
- Rails - Engine/generator/radiator mounting
Starting / Charging System
- 24 Volt electric starting motor
- Battery and battery rack w/cables
- Battery disconnect switch
General
- Right hand servicing
- Flywheel and flywheel housing-SAE No. 00
- SAE standard rotation
Controller
- EMCP 4.2B
Telematics
- Ethernet
Alternator
- Random wound
- Internal excitation (IE)
Power Termination
- Busbar
- Busbar
Optional Equipment
Air Inlet System
- Remote air inlet adapters
- Dual element air cleaners
- Air inlet protection
- Heavy duty air cleaners
Circuit breakers
- Cable entry options
- Control packaging for enclosures
- Load take off; IEC standard hole
- Busbar power connections
- Center posts busbars
- EMAX breakers
Power Termination
- Circuit breakers, IEC compliant
Air Cleaner
- Dual element with service indicator
Control Panels
- Annunciator modules
- Generator temperature monitoring
- Auxiliary box
- Remote speed adjust
- Busbar connections
- Vandal proof panel door
- Voltage raise/lower switch
- EMCP 4.3, EMCP 4.4
- Local and remote monitoring
- Language options
- Customer interface options
- External box clips
- EMAX breaker connections
- Governors
Cooling System
- Heat exchangers
- Water level switch gauges
- Radiator duct flanges
- Optional Serpentine radiators
European Certifications
Exhaust System
- Through wall installation kit
- Muffler mounting kits
- Mufflers
- Flexible fittings
Fuel System
- Fuel coolers
- Primary fuel filter
Starting
- Standard batteries
- Oversized batteries
- Battery charger - 10A
- Battery charger - 20A
- Battery charger - 40A
- Battery charger - 50A
- Air starter(s)
- Jacket water heater
Generators and attachments
- Generators
- 3 Phase, Random wound, Internal excitation (IE)
- Internal excitation (IE)
- Number of leads: 6
- Pitch: 0.6667
Instrumentation
- Pyrometers and thermocouples
- Thermocouples
Lube System
- Oil level regulator
- Electric prelube pumps
- Manual prelube sump pumps
Protection System
- Explosion relief valves
Special Tests / Reports
- IBC seismic Certification
- CSA test and certification
- PGS Test report @ 1.0 power factor
- Neutral ground certificate
- PGS Test report @ 0.8 power factor
Cooling
- No Radiator
- High Ambient Radiator
Starting / Charging System
- 10 and 20 Amp Battery chargers
- Charging alternators - 50 Amp
- ETHER starting aids
- 24 Volt battery set - Dry
- Jacket water heaters
Crankcase Ventilation System
- Filtered crankcase ventilation
- Closed filtered crankcase ventilation
General
- Engine barring group
Muffler
- Industrial grade (15 dB)
- Critical grade (25 dB)
- Hospital grade (35 dB)
Mounting System
- Spring type vibration isolators
- Spring vibration Isolators
- Seismic rated vibration isolators
Controller
- EMCP 4.3
- EMCP 4.4
Controller attachments
- Local annunciator module
- Remote annuciator module
- Expansion I/O module
- Remote monitoring software
Telematics
- Cellular
Extended service terms
- 2 year (prime)
- 3 year
- 5 year
- 10 year
Extended service coverage
- Silver
- Gold
- Platinum
- Platinum plus
Alternator
- Form wound
- Permanent Magnet (PM) Excitation
Alternator Temperature rise (over 40°C ambient)
- 80°C
- 105°C
- 125°C/130°C
- 150°C
Alternator Output Voltage
- 380V
- 400V
- 415V
- 6300V
- 6600V
- 6900V
- 10000V
- 10500V
- 11000V
Alternator attachments
- Anti-condensation space heater
- Stator and bearing temperature monitoring and protection
Circuit breaker
- 5000A
- IEC
- 3-pole
- Manually operated
- Electrically operated
Trip Unit
- LSI
- LSI-G
- LSIG-P
Ancilliary Equipment
- Automatic transfer switch (ATS)
- Paralleling switchgear
- Paralleling controls
Certifications
- EU & GB Declaration of Conformity
- EU & GB Declaration of Incorporation
- Eurasian Conformity (EAC)
- Telecommunication Lab of China